hhkb: Measurement of overall power draw
This commit is contained in:
parent
bd28119dd8
commit
f4ffdb8e83
1 changed files with 14 additions and 0 deletions
|
|
@ -46,3 +46,17 @@ X'tal --+---->Prescaler-------> System Clock
|
||||||
+---------------------> USB PLL
|
+---------------------> USB PLL
|
||||||
|
|
||||||
Design Decision: Install 16MHz crystal on board with using clock rescaler.
|
Design Decision: Install 16MHz crystal on board with using clock rescaler.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
2018/03/24
|
||||||
|
Pro2 overall:
|
||||||
|
with stock 139.3mA
|
||||||
|
with TMK 40.8mA
|
||||||
|
with TMK_BT 55.2mA without battery(USB)
|
||||||
|
with TMK_BT 93-100mA without battery(BT)
|
||||||
|
|
||||||
|
JP overall:
|
||||||
|
with stock 37.1mA
|
||||||
|
with TMK 41.6mA
|
||||||
|
|
|
||||||